Weight | 0.907185 kg |
---|---|
Dimensions | 6 × 6 × 7 cm |
Lightning Protector 600V
$ 161.66
The MidNite Solar Surge Protector Device (MNSPD) is a Type 1 device per UL1449 rev3. It is designed for both AC and DC systems and provides protection to service panels, load centers or where the SPD is directly connected to the electronic device requiring protection.
Protection for gridtie PV combiners and inverter input circuits.
Listed by ETL for US & Canada
Related products
Din Rail Breaker DC – 150
MidNite’s breakers are rated to break the full rated load at the rated voltage repeatedly, with NO DAMAGE. Always use a properly sized breaker for disconnecting. SPECIFY AMP SIZE when ordering.
Available sizes: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 12, 15, 20, 30, 40, 50 and 63 amp 150VDC din rail mount breaker.
All MidNite circuit breakers hold 100% rated current independent of ambient temperature.
Listed by ETL for US & Canada
Fuse Holder
Touch Safe Fuse Holder for10x38 mm fuses 600VDC 30 amp Din rail mount. Use in the MNPV combiners for high voltage string inverters.
UL & CSA Listed
Lightning Protector 300V
The MidNite Solar Surge Protector Device (MNSPD) is a Type 1 device per UL1449 rev3. It is designed for both AC and DC systems and provides protection to service panels, load centers or where the SPD is directly connected to the electronic device requiring protection.
Protection for Classic and other charge controllers, off grid PV combiners and 120/240 VAC circuits.
Listed by ETL for US & Canada
Din Rail Breaker DC – 300
MidNite’s breakers are rated to break the full rated load at the rated voltage repeatedly, with NO DAMAGE. Always use a properly sized breaker for disconnecting. SPECIFY AMP SIZE required when ordering.
Available sizes: 7, 10, 12, 15, 20, 30, 50 amp 300VDC din rail mount breaker.
All MidNite circuit breakers hold 100% rated current independent of ambient temperature.
Listed by ETL for US & Canada
Midnite MNPV8HV-Disco 3R
Midnite MNP8HV-Disco 3R
The MidNite Solar MNPV8HV Disco 3R can be re-configured in the field to be used with non-isolated inverters where both the positive and negative need to be disconnected. This also allows these to be used to combine and disconnect two arrays feeding two separate isolated inverters. This disconnecting and standard pre-wired combiner is plug and play, saving both time and money in the field. MidNite Solar’s Rapid Shutdown system, which includes MidNite’s disconnecting combiners, meet the requirement of the 2014 NEC 690.12 code.
Comes with 4 fuses and a single lightening arrestor
5 year Warranty. Made in USA
Listed by ETL for US & Canada
Convertible configuration (field configurable)
Eight strings combined for up to 160 Amps single 230 Amp/600V single pole disconnect)
4 + 4 positive strings, separate PV+ and PV- for use with 2 inverters (2 pole 115 Amp disconnect)
Four strings positive, four strings minus for use with non-isolated inverters (2 pole 115 Amp disconnect)
Disconnect has built in shunt trip with positive feedback.
Birdhouse compatible. Load Break Rated.
Optional PV connected power supply. Optional AC connected power supply for redundancy.
Type 3R aluminum enclosure (no rust, won’t turn to dust)
90o C connections. See thru deadfront & color coded busbar guards included.
Fuseholders (MNTS) installed. 15a/600v fuses installed. 600 volt max.
Midnite MNPV4HV-Disco 3R BSC
Midnite MNP4HV-Disco 3R BSC
The MNPV4HV-DISCO 3R-BSC’s red handle is lockable in the off position.
Type 3R aluminum enclosure (no rust, won’t turn to dust)
90 degrees Celcius terminals
See through dead front & color coded busbar guards included
Meets 2011 NEC
Load Break Rated
Model number MNPV4HV Disco 3R Basic
Warranty – 5 yrs.
Listed by ETL for US
Made in the USA
Enclosure only
Breakers/fuse holders sold separately.
200A Replacement T Fuse
200 to 400 amp Replacement Fuse for the Deltec PFB T Fuse
Specify fuse amp when ordering. Available in 200, 300, 350 and 400 amps.